Outdoor Broadband Triplexer | TPO-397236-S-xx |
|||
|
Overview
The CCI Outdoor Broadband Triplexer combines the frequency ranges 390-960 MHz, 1710-2180 MHz, and 2300-2700 MHz onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum onto existing sites, while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. An optional twin unit with two Triplexers mounted on a single bracket is also available. Technical Description: The Outdoor Broadband Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the 390-960 band on port 1, the 1695-2200 band on port 2, and the 2300-2700 band on port 3 onto a common feeder line. The fully weatherproof tower mount outdoor Triplexer provides DC and AISG signal pass-through, enabling power and control for TMA's & RET antennas. The Triplexer is available with DC/AISG pass options including a smart bias-tee or AISG modem and output port. The Smart Bias-Tee architecture passes the DC and AISG carrier frequency from any one of the input ports to the common port while blocking the DC and AISG signals from being re-injected into the other input ports. The Triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | 4 (Common) | 390 - 960 | 18 dB minimum, 20 dB typical |
2300 - 2700 | 18 dB minimum, 20 dB typical | ||
1695 - 2200 | 18 dB minimum, 20 dB typical | ||
1 (390-600/700/800/900) | 390 - 960 | 18 dB minimum, 20 dB typical | |
2 (DCS/IMT2100) | 1695 - 2200 | 18 dB minimum, 20 dB typical | |
3 (2300-2700) | 2300 - 2700 | 18 dB minimum, 20 dB typical | |
Insertion Loss | 4 to 1 (COMMON to 390-600 /700/800/900) |
390 - 960 | 0.3 dB maximum |
4 to 2 (COMMON to 1695-2200) |
2300 - 2700 | 0.3 dB maximum | |
4 to 3 (COMMON to 2300-2700) |
1695 - 2200 | 0.3 dB maximum | |
Isolation | 4 to 1 (COMMON to 390-600 /700/800/900) |
1695 - 2200 | 50 dB minimum |
2300 - 2700 | 50 dB minimum | ||
4 to 2 (COMMON to 1695-2200) |
390 - 960 | 50 dB minimum | |
2300 - 2700 | 50 dB minimum | ||
4 to 3 (COMMON to 2300-2700) |
390 - 960 | 50 dB minimum | |
1695 - 2200 | 50 dB minimum |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 200 W maximum per port |
Peak Envelope Power | 2 kW maximum per port |
IM Performance(all ports) | <-117 dBm (-160 dBc) typical (2× +43 dBm tones) all bands |
DC Pass Current/AISG Pass (Any Port to COMMON port) | 3A/AISG signal (2.176 Mhz) per AISG 2.0 |
Mechanical Specification
Model | TPO-392226-S-Sx | TPO-392226-S-Tx |
Modularity | Single | Twin |
Connectors | 4 × 4.3-10 or 7-16 female | 8 × 4.3-10 or 7-16 female |
Dimensions w/Bracket | 10.08 × 5.79 × 2.60 in. (256.0 × 147.0 ×66 mm) |
10.08 × 5.79 × 4.65 in. (256.0 × 147.0 × 118 mm) |
Housing Dimensions | 6.61 × 5.79 × 2.01 in. (168.0 × 147.1 × 51.0 mm) - per Triplexer | |
Weight | 4.85 lbs (2.2 kg) | 9.7 lbs (4.4 kg) |
Mounting | Pole/Wall mounting bracket |
Outdoor Broadband Triplexer Outline Drawing |
Parts & Accessories
TPO-397236-S-S1 | Single Broadband Triplexer with 7-16 connectors and Smart Bias-T for DC/AISG pass through |
TPO-397236-S-S2 | Single Broadband Triplexer with 4.3-10 connectors and Smart Bias-T for DC/AISG pass through |
TPO-397236-S-T1 | Twin Broadband Triplexer with 7-160 connectors and Smart Bias-T for DC/AISG pass through |
TPO-397236-S-T2 | Twin Broadband Triplexer with 4.3-10 connectors and Smart Bias-T for DC/AISG pass through |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|