The CCI Outdoor Broadband Triplexer combines the frequency ranges 555-960 MHz, 1695-2200 MHz, and 2305-2690 MHz onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum onto existing sites, while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. An optional twin unit with two Triplexers mounted on a single bracket is also available. Technical Description: The Outdoor Broadband Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the 600/700/850/900 bands on port 1, the AWS/PCS bands on port 2, and the WCS/BRS bands on port 3 onto a common feeder line. The fully weatherproof tower mount unit has DC/AISG pass through Smart DC with full autosense DC capability, which allows DC/AISG pass through in both the combine and split paths. The Triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | Common | 555 - 960 | 18 dB minimum, 20 dB typical |
1695 - 2200 | 18 dB minimum, 20 dB typical | ||
2305 - 2690 | 18 dB minimum, 20 dB typical | ||
600/700/850/900 | 555 - 960 | 18 dB minimum, 20 dB typical | |
AWS/PCS | 1695 - 2200 | 18 dB minimum, 20 dB typical | |
WCS/BRS | 2305 - 2690 | 18 dB minimum, 20 dB typical | |
Insertion Loss | COMMON to 600/700/850/900 | 555 - 960 | 0.15 typical, 0.2 dB maximum |
COMMON to AWS/PCS | 1695 - 2200 | 0.2 dB typical, 0.35 dB maximum | |
COMMON to WCS/BRS | 2305 - 2690 | 0.2 dB typical, 0.35 dB maximum | |
Isolation | COMMON to 600/700/850/900 | 1695 - 2200 | 50 dB minimum |
2305 - 2690 | 50 dB minimum | ||
COMMON to AWS/PCS | 555 - 960 | 50 dB minimum | |
2305 - 2690 | 50 dB minimum | ||
COMMON to WCS/BRS | 555 - 960 | 50 dB minimum | |
1695 - 2200 | 50 dB minimum | ||
Group Delay ± Group Delay Variation | COMMON to 600/700/850/900 | 555 - 960 | 2 ns ± 0.5 ns |
COMMON to AWS/PCS | 1695 - 2200 | 11 ns ± 6.0 ns | |
COMMON to WCS/BRS | 2305 - 2690 | 11 ns ± 6.0 ns |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 300 W (+54.77 dBm) max. |
Peak Envelope Power | 5 kW (+667 dBm) max. |
IM Performance (all ports) | <-117 dBm (-160 dBc) typical (2× +43 dBm tones) all bands |
DC/AISG | |
Smart DC | DC path is automatically determined, when the unit is used as a combiner or splitter |
Combine mode standard priority* | 1. 2305 - 2690 MHz 2. 555 - 960 MHz 3. 1695 - 2200 MHz *Customer can request a different priority at time of purchase |
Combine Path Operation | The port with DC voltage (7 - 30 V) is automatically passed to the COMMON Port. If more than one port has DC voltage present, the port with the highest priority is passed. If a short circuit is detected on the COMMON Port DC/AISG is disabled for the entire unit. |
Split Path Operation | DC/AISG pass through will be disabled for all ports where a short circuit is detected and DC/AISG will be passed to all other ports. |
DC Bypass Power-Up to Operating Time | <100 ms |
Current Consumption @ voltage | 35 mA typical, 50 mA maximum (7.0 to 30 VDC) |
Current (Single Path) | 2.5 A maximum |
Current Common | 2.5 A maximum |
AISG signal | 2.176 MHz, per AISG 2.0 |
Mechanical Specification
Model | Single (3 In, 1 Out) | Twin (6 In, 2 Out) |
Modularity | Single | Twin |
Ports, In-Line | 3 x BTS, 1 x ANT | 6 x BTS, 2 x ANT |
Connectors | 4 × 4.3-10 female | 8 × 4.3-10 female |
Dimensions w/Bracket | 10.09 × 8.27 × 3.32 in. (256.2 × 210.0 × 84.4 mm) |
10.09 × 8.76 × 6.28 in. (256.2 × 222.5 × 159.4 mm) |
Housing Dimensions | 6.16 × 8.27 × 2.79 in. (156.4 × 210.0 × 70.8 mm) |
6.16 × 8.27 × 5.74 in. (156.4 × 210.0 × 145.8 mm) |
Weight | 9.0 lbs (4.1 kg) | 17.4 lbs (7.9 kg) |
Frontal Wind Load | 111.3 N @150km/hour | 111.3 N @150km/hour |
Lateral Wind Load | 35.0 N @150km/hour | 70.0 N @150km/hour |
Housing Ground Lug | 1 x M8 | 1 x M8 |
Ground Screw on Mounting Bracket | Not Applicable | |
Finish | Housing - Powder Coat Gray; Bracket(s) - 304 Stainlees Steel (Passivated per ASTM A-967) |
|
Available Mast Diameter | 3 to 6 inches (76.2 to 1542.4 mm) | |
Pole Mounting | Use integral mouting bracket and the 2 band clamps provided (Orientation, the connectors will be in-line with mast) |
|
Wall Mounting | Use integral mouting bracket and appropriate fasteners (Orientation, no restrictions) |
Single Outdoor Broadband Triplexer Outline Drawing | |
Twin Outdoor Broadband Triplexer Outline Drawing |
Parts & Accessories
TPO-697136B-D-S2 | Single Outdoor Broadband Triplexer with 4.3-10 connectors and Smart DC for DC/AISG pass through in either direction on any port |
TPO-697136B-D-T2 | Twin Outdoor Broadband Triplexer with 4.3-10 connectors and Smart DC for DC/AISG pass-through in either direction on any port |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|