2100 MHz Spectrum Sharing Combiner | PFC-1921-6xx | |||
![]() |
|
Overview
CCI’s Twin Low Loss fully integrated Filter-Combiner combines two operators or two technologies (eg GSM and LTE) on sub-bands of the 2100 band onto a single feeder without the insertion loss normally associated with passive combiners. The unit is fully passive and delivers a matched low insertion loss solution for the sharing of common feeder lines and antennas. The unit is a totally passive low loss filter and no power is required. DC pass is provided as an option if required. The input ports will sense the DC signal and enable DC to pass through to the antenna port. The unit is housed in a single rack-mounted 19" by 1U assembly and can be used with other CCI products for further sector enhancement. Outdoor packaging can be provided. Typical deployment uses two identical units per sector, enabling Tx/Rx from both operator BTS ports to combine onto 2 main feeder lines. Technical Description: Internal duplexers deliver signal to independent Tx and Rx filter combiners with ceramic resonators, enabling a high level of control and performance to maintain good isolation while minimizing insertion loss. Stages are kept to a minimum to maximize power and efficiency. Transmit paths are fully isolated from Receive paths to prevent intermodulation products. |
![]() |
Electrical
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | COMMON | Operator 1 RX/TX | 18 dB minimum, 20 dB typical |
Operator 2 RX/TX | 18 dB minimum, 20 dB typical | ||
RX/TX 0 | Operator 1 RX/TX | 18 dB minimum, 20 dB typical | |
RX/TX 1 | Operator 2 RX/TX | 18 dB minimum, 20 dB typical | |
Insertion Loss Guardband≤ 5.0 MHz |
RX/TX 0 to COMMON | Operator 1 RX & Operator 2 RX | 0.9 dB maximum |
RX/TX 1 to COMMON | Operator 1 TX & Operator 2 TX | 0.9 dB maximum | |
Insertion Loss Guardband > 5.0 MHz & < 15.0 MHz |
RX/TX 0 to COMMON | Operator 1 RX & Operator 2 RX | 0.7 dB maximum |
RX/TX 1 to COMMON | Operator 1 TX & Operator 2 TX | 0.7 dB maximum | |
Insertion Loss Guardband ≥ 15.0 MHz |
RX/TX 0 to COMMON | Operator 1 RX & Operator 2 RX | 0.5 dB maximum |
RX/TX 1 to COMMON | Operator 1 TX & Operator 2 TX | 0.5 dB maximum | |
Isolation Guardband ≤ 5.0 MHz |
RX/TX 0 to RX/TX 1 | Operator 1 RX & Operator 2 RX |
25 dB minimum, 28 dB typical |
RX/TX 0 to RX/TX 1 | Operator 1 TX & Operator 2 TX |
25 dB minimum, 28 dB typical |
|
Isolation Guardband > 5.0 MHz & < 15.0 MHz |
RX/TX 0 to RX/TX 1 | Operator 1 RX & Operator 2 RX |
27 dB minimum, 29 dB typical |
RX/TX 0 to RX/TX 1 | Operator 1 TX & Operator 2 TX |
27 dB minimum, 29 dB typical |
|
Isolation Guardband ≥ 15.0 MHz |
RX/TX 0 to RX/TX 1 | Operator 1 RX & Operator 2 RX |
30 dB minimum, 32 dB typical |
RX/TX 0 to RX/TX 1 | Operator 1 TX & Operator 2 TX |
30 dB minimum, 32 dB typical |
|
*See chart below for Operator 1 RX/TX and Operator 2 RX/TX frequencies |
Model Number | Operator 1 | Guard Band | Operator 2 | ||
RX | TX | RX | TX | ||
PFC-1921-040 | 1920.1 - 1935.1 | 2110.1 - 2125.1 | 5.0 | 1940.1 - 1950.1 | 2130.1 - 2140.1 |
PFC-1921-619 | 1920.0 - 1935.0 | 2110.0 - 2125.0 | 15.0 | 1950.0 - 1965.0 | 2140.0 - 2155.0 |
PFC-1921-620 | 1919.9 - 1924.9 | 2109.9 - 2114.9 | 15.0 | 1939.9 - 1944.9 | 2129.9 - 2134.9 |
PFC-1921-623 | 1920.0 - 1935.0 | 2110.0 - 2125.0 | 35.0 | 1970.0 - 1980.0 | 2160.0 - 2170.0 |
PFC-1921-630 | 1920.3 - 1940.3 | 2110.3 - 2130.3 | 10.0 | 1950.3 - 1965.3 | 2140.3 - 2155.3 |
PFC-1921-640 | 1919.9 - 1935.0 | 2109.9 - 2125.0 | 4.9 | 1939.9 - 1965.1 | 2129.9 - 2155.1 |
PFC-1921-655 | 1920.1 - 1930.1 | 2110.1 - 2120.1 | 5.0 | 1935.1 - 1950.1 | 2125.1 - 2140.1 |
PFC-1921-665 | 1935.1 - 1945.0 | 2125.1 - 2135.0 | 4.9 | 1949.9 - 1964.9 | 2139.9 - 2154.9 |
Contact sales for additional operator frequency combinations or guard band less than 4.9 MHz; unit is factory settable with guardband ≥ 4.9 MHz and ≤ 35.0 MHz |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 100 W max. (Input ports) |
300 W max. (Common port) | |
Peak Envelope Power | 2 kW max. (all ports) |
Intermodulation Performance(at ANT port in RX band) | <-117 dBm (-160 dBc) typical (2 × +43 dBm tones) all bands |
DC Pass Current/AISG Pass any port to Common Port) | 5A/AISG signal (2.176 MHz) per AISG 2.0 (Auto-detect) |
![]() |
Mechanical
Connectors | 6 × 7-16 DIN female |
Dimensions(body only)(H×W×D) | 8.43 × 17.44 × 1.73 in. (214.0 × 443.0 × 44.0 mm) |
Dimensions (with rack mount+Conn)(H×W×D) | 9.61× 19.01 × 1.73 in. (244.0 x 483.0 x 44.0 mm) |
Weight with brackets | 19.8 lbs (9 kg) |
Mounting | Rack Mount |
![]() |
|
PFC-1921-6xx 2100 MHz Spectrum Sharing Combiner Outline Drawing |
Accessories
SCU-AISG2-3 | AISG 2.0 Site Controller |
RET-CBK | AISG Cable Kit |
BT-0723-DMDF-AG-O | DIN-Male RF Port, DIN-Female RF+DC+AISG Port |
BT-0723-DFDM-AG-O | DIN-Female RF Port, DIN-Male RF+DC+AISG Port |
BT-0723-DFDF-AG-O | DIN-Female RF Port, DIN-Female RF+DC+AISG Port |
Parts & Accessories
PFC-1921-6xx | Spectrum Sharing 2100 MHz Rack Mount Combiner with Smart Bias-Tee and 7/16 connectors |
*See chart below for Operator 1 RX/TX and Operator 2 RX/TX frequencies |
Model Number | Operator 1 | Guard Band | Operator 2 | ||
RX | TX | RX | TX | ||
PFC-1921-040 | 1920.1 - 1935.1 | 2110.1 - 2125.1 | 5.0 | 1940.1 - 1950.1 | 2130.1 - 2140.1 |
PFC-1921-619 | 1920.0 - 1935.0 | 2110.0 - 2125.0 | 15.0 | 1950.0 - 1965.0 | 2140.0 - 2155.0 |
PFC-1921-620 | 1919.9 - 1924.9 | 2109.9 - 2114.9 | 15.0 | 1939.9 - 1944.9 | 2129.9 - 2134.9 |
PFC-1921-623 | 1920.0 - 1935.0 | 2110.0 - 2125.0 | 35.0 | 1970.0 - 1980.0 | 2160.0 - 2170.0 |
PFC-1921-630 | 1920.3 - 1940.3 | 2110.3 - 2130.3 | 10.0 | 1950.3 - 1965.3 | 2140.3 - 2155.3 |
PFC-1921-640 | 1919.9 - 1935.0 | 2109.9 - 2125.0 | 4.9 | 1939.9 - 1965.1 | 2129.9 - 2155.1 |
PFC-1921-655 | 1920.1 - 1930.1 | 2110.1 - 2120.1 | 5.0 | 1935.1 - 1950.1 | 2125.1 - 2140.1 |
PFC-1921-665 | 1935.1 - 1945.0 | 2125.1 - 2135.0 | 4.9 | 1949.9 - 1964.9 | 2139.9 - 2154.9 |
Contact sales for additional operator frequency combinations or guard band less than 4.9 MHz; unit is factory settable with guardband ≥ 4.9 MHz and ≤ 35.0 MHz |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|