DAS Interface Module | DAST-700-MODA-30 DAST-700-MODB |
|||
|
Overview
CCI’s 700 MHz DAS Interface Modules provide an integrated, convenient, and single connection point when using single or multiple LTE base stations with a common DAS system. The unique architecture of the CCI DAS Interface Modules can accommodate both MIMO and SIMO configurations, including two operators providing MIMO coverage on a common MIMO DAS System. The internal triplexers utilized in the Interface Modules can simultaneously cover both ‘Upper’ and ‘Lower’ 700 MHz band such that the same Interface Module can be used for either band implementation.
Integrated leveling controls are provided in both the uplink and downlink path in order to achieve the proper link balance to the DAS system for each base station channel. The LTE E-Node B’s are connected directly to the DAS Interface Module without the need to attenuate power as the DAS tray provides integrated high power attenuation for each channel with an adjustment range of 30 dB with 1 dB increments for the TX path, and 30 dB with 1 dB increments for the RX path. The DAS Tray is a completely passive assembly with no external power requirement thus providing the highest reliability and convenient installation. An optional duplexed connection To/From DAS is available on MODA (Module A). |
Configuration Diagram
LTE MIMO and SIMO Configuration Diagrams | ||
Figure I - Shared Dual MIMO E-Node B Configuration with MIMO Output to DAS System | Figure II - Single MIMO E-Node B Configuration with MIMO Output to DAS System | |
Figure III - Single SIMO E-Node B Configuration with SIMO Output to DAS System | Figure IV - Shared SIMO E-Node B Configuration with SIMO Output to DAS System |
Figure V - Single MIMO E-Node B Configuration with SIMO Output to DAS System |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification | |
DAST-700-MODA | DAST-700-MODB | |||
Return Loss | TX/RX | 698 - 716 | 18 dB typ. | |
728 - 768 | 18 dB typ. | |||
776 - 798 | 18 dB typ. | |||
RX | 698 - 716 | 18 dB typ. | ||
776 - 798 | 18 dB typ. | |||
RX IN | 698 - 716 | 18 dB typ. | ||
776 - 798 | 18 dB typ. | |||
TX OUT | 728 - 768 | 18 dB typ. | ||
TX IN | 728 - 768 | 18 dB typ. | ||
Insertion Loss | TX/RX to TX OUT | 728 - 768 | 18.5 - 48.5 dB, adjustable in 1dB steps | 14 dB avg. |
TX IN to TX OUT | 728 - 768 | 4.5 - 34.5 dB, adjustable in 1dB steps | N/A | |
RX IN to TX/RX | 698 - 716 | 9 - 39 dB, adjustable in 1dB steps | 1 dB avg. | |
776 - 798 | 9 - 39 dB, adjustable in 1dB steps | 1 dB avg. | ||
RX IN to RX | 698 - 716 | 9 - 39 dB, adjustable in 1dB steps | N/A | |
776 - 798 | 9 - 39 dB, adjustable in 1dB steps | N/A | ||
Isolation | TX/RX to RX IN | 728 - 768 | 65 dB plus variable attenuator setting | 60 dB |
TX/RX to RX | 728 - 768 | 80 dB | N/A |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 100 W max. at TX/RX port |
Peak Envelope Power | 2 kW max. |
Intermodulation Performance | <-118 dBm (-161 dBc) typical (2 × +43 dBm tones) |
Mechanical Specification
Model | DAST-700-MODA | DAST-700-MODB |
TX/RX IN Connectors | 7-16 DIN female | 7-16 DIN female |
RX IN Connectors | 2 × 7-16 DIN female; 1 × N-Female | 1 × N-female |
TX IN Connectors | 1 × N-female | 1 × N-female |
TX OUT (to DAS), RX IN (from DAS) Connectors | 1 × QMA female | NA |
Dimensions (H(2U)×W×D) | 3.5 × 8.772× 16 in. (88.9 × 222.8 × 406.4 mm) | 3.5 × 8.772× 16 in. (88.9 × 222.8 × 406.4 mm) |
Weight (w/o Bracket) | 18.9 lbs (8.6 kg) | 17.1 lbs (7.75 kg) |
Mounting | Mount in Universal DAS Tray (TRA-DAS-UNIV 19 in. Rack Mountable) |
Block Diagram
LTE MIMO and SIMO Configuration Detailed Diagrams | ||
Figure I - Shared Dual MIMO E-Node B Configuration with MIMO Output to DAS System | ||
Figure II - Single MIMO E-Node B Configuration with MIMO Output to DAS System |
Figure III - Single SIMO E-Node B Configuration with SIMO Output to DAS System |
Figure IV - Shared SIMO E-Node B Configuration with SIMO Output to DAS System | Figure V - Single MIMO E-Node B Configuration with SIMO Output to DAS System |
Options | |
-DPX "Single Duplexed connection To/From DAS" (on MODA only) Note: adds 3 dB to Transmit and Receive Insertion Loss |
Parts & Accessories
Configuration | Configuration Description | Quantity required: DAST-700-MODA-30 "700 MHz DAS Module A" |
Quantity required: DAST-700-MODA "700 MHz DAS Module B" |
Quantity required: TRA-DAS-UNIV "Universal Tray for DAS Interface Modules" |
I | Shared Dual MIMO E-Node B Configuration with MIMO Output to DAS System | 2 | 2 | 2 |
II | Single MIMO E-Node B Configuration with MIMO Output to DAS System | 2 | - | 1 |
III | Single SIMO E-Node B Configuration with SIMO Output to DAS System | 1 | - | 1 |
IV | Shared Dual SIMO E-Node B Configuration with SIMO Output to DAS System | 1 | 1 | 1 |
V | Single MIMO E-Node B Configuration with SIMO Output to DAS System | 1 | 1 | 1 |
|