Broadband Triplexer Combiner | TPO-182236-E-T2 | |||
|
Overview
The CCI Broadband Triplexer combines three bands, DCS (1710-1880), UMTS 2100 (1920-2170) and 2300/2600 band (2300-2700) onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum including LTE 2600 to existing sites while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. Technical Description: The Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the DCS, UMTS 2100, and 2300/2600 bands on a common feeder line. The fully weatherproof tower mount outdoor triplexer is orderable with DC block on all ports or DC and AISG signal pass-through on any of the band specific ports. When configured with pass-through the Triplexer provides power and control for TMA's & RET antennas. DC/AISG pass options include Smart DC with autosense. The triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | Common | 1710 - 1880 | 20 dB minimum |
1920 - 2170 | 20 dB minimum | ||
2300 - 2700 | 20 dB minimum | ||
DCS | 1710 - 1880 | 20 dB minimum | |
UMTS 2100 | 1920 - 2170 | 20 dB minimum | |
LTE Band | 2300 - 2700 | 20 dB minimum | |
Insertion Loss | COM to DCS | 1710 - 1880 | 0.4 dB typical, 0.5 dB maximum |
COM to UMTS 2100 | 1920 - 2170 | 0.4 dB typical, 0.5 dB maximum | |
COM to LTE Band | 2300 - 2700 | 0.4 dB typical, 0.5 dB maximum | |
Isolation | COM to DCS | 1920 - 2170 | 50 dB minimum |
2300 - 2700 | 50 dB minimum | ||
COM to UMTS 2100 | 1710 - 1880 | 50 dB minimum | |
2300 - 2700 | 50 dB minimum | ||
COM to LTE Band | 1710 - 1880 | 50 dB minimum | |
1920 - 2170 | 50 dB minimum | ||
Group Delay | COM to DCS | 1710 - 1880 | 25 ns |
COM to UMTS 2100 | 1920 - 2170 | 27 ns | |
COM to LTE Band | 2300 - 2700 | 17 ns | |
Group Delay Variation | COM to DCS | 1710 - 1880 | 10 ns |
COM to UMTS 2100 | 1920 - 2170 | 8 ns | |
COM to LTE Band | 2300 - 2700 | 7 ns |
General Characteristics | |||
Impedance | 50 ohms | ||
Continuous Average Power (RMS) | 200 W (+53 dBm) per input port | ||
Peak Envelope Power | 2 kW (+63 dBm) maximum at COMMON | ||
Intermodulation Performance (all ports) | <-117 dBm (-160 dBc) typical all bands, 2× +43 dBm carriers |
DC/AISG | |
DC Autosense | DC path is automatically determined, when the unit is used as a combiner or splitter |
Combine mode priority | 1. 1710 - 1880 MHz 2. 2300 - 2700 MHz 3. 1920 - 2170 MHz 4. 690 - 960 MHz |
DC Autosense Combine Mode Operation | The port with DC voltage is automatically passed to the COMMON Port. If more than one port has DC voltage, the port with the highest priority is passed. If a short circuit is detected on the COMMON Port DC/AISG is disabled for the entire unit. |
DC Autosense Splitter Mode Operation | DC/AISG pass through will be disabled where a short circuit is detected and DC/AISG will be passed to all other ports |
DC Bypass Power-Up to Operating Time | <100 ms |
Current Consumption @ TBD voltage | 35 mA typical, 50 mA maximum (7.0 to 30 VDC) |
Current (Single Path) | 2.5 A maximum |
Current Common | 2.5 A maximum |
AISG signal | 2.176 MHz, per AISG 2.0 |
Mechanical Specification
Model | TPO-182236-S-Sx (3 In, 1 Ouit) |
TPO-182236-S-Tx (6 In, 2 Out) |
Modularity | Single | Twin |
Ports, In-Line | 3 x BTS, 1 x ANT | 6 x BTS, 2 x ANT |
Connectors | 4 x 4.3-10 female | 8 x 4.3-10 female |
Dimensions with brackets | 237.0x 169.0 x 63.5 mm | 237.0 x 169.0 x 117.5mm |
Housing Dimensions | 146.0 x 169.0 x 48.5 mm - per Diplexer | |
Weight with brackets | 2.3 Kg | 4.8 Kg |
Housing Ground Lug | 1 x M8 | 1 x M8 |
Finish | Housing - Powder Coat Gray; Bracket(s) - 304 Stainless Steel (Passivated per ASTM A-967) |
|
Packaging Size | TBD | 17.91 x 12.4 x 15.35 in. (455 x 315 x 390 mm) for 4 pcs. |
Packagiing Weight | TBD | 45.3 Lbs. (20.6 kg) for 4 pcs. |
Available Mast Diameter | 3 to 6 inches (76.2 to 152.4 mm) | |
Pole Mounting | Use integral mouting bracket and the 2 band clamps provided (Orientation, the connectors will be in-line with mast) |
|
Wall Mounting | Use integral mouting bracket and appropriate fasteners (Orientation, no restrictions) |
Outdoor Broadband Triplexer Outline Drawing |
Product Information
TPX-182236 Outdoor Broadband Triplexer outline drawing |
Parts & Accessories
TPO-182236-E-S2 | Single 1710-1880/1920-2170/2300-2700 Triplexer with 4.3-10 connectors and Smart DC for DC/AISG pass through in either direction on any port |
TPO-182236-E-T2 | Twin 1710-1880/1920-2170/2300-2700 Triplexer with 4.3-10 connectors and Smart DC for DC/AISG pass through in either direction on any port |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|