Outdoor Broadband Triplexer | TPO-333228-xxx |
|||
|
|||
Overview
The CCI Outdoor Broadband Triplexer combines the frequency ranges 380-2690 MHz, 3300-4200 MHz, and 5150-5925 MHz onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum onto existing sites, while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. An optional twin unit with two Triplexers mounted on a single bracket is also available. Technical Description: The Outdoor Broadband Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the 380-2690 band on port 1, the 3300-4200 band on port 2, and the 5150-5925 band on port 3 onto a common feeder line. The fully weatherproof tower mount outdoor Triplexer provides DC and AISG signal pass-through, enabling power and control for TMA's & RET antennas. The Triplexer is available with DC/AISG pass through only on the 380-2690 path to common. The Triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | COM | 380 - 2690 | 18 dB minimum, 20 dB typical |
3300 - 4200 | 18 dB minimum, 20 dB typical | ||
5150 - 5925 | 18 dB minimum, 20 dB typical | ||
1 (380 - 2690) | 380 - 2690 | 18 dB minimum, 20 dB typical | |
2 (3300 - 4200) | 3300 - 4200 | 18 dB minimum, 20 dB typical | |
3 (5150 - 5925) | 5150 - 5925 | 18 dB minimum, 20 dB typical | |
Insertion Loss | COM to Port 1 | 380 - 2690 | 0.1 dB Typical, 0.15 dB maximum |
COM to Port 2 | 3300 - 4200 | 0.25 dB typical, 0.35 dB maximum | |
COM to Port 3 | 5150 - 5925 | 0.35 dB typical, 0.45 dB maximum | |
Isolation | COM to Port 1 | 3300 - 4200 | 50 dB minimum |
5150 - 5925 | 50 dB minimum | ||
COM to Port 2 | 380 - 2690 | 50 dB minimum | |
5150 - 5925 | 50 dB minimum | ||
COM to Port 3 | 380 - 2690 | 50 dB minimum | |
3300 - 4200 | 50 dB minimum |
General Characteristics | |||
Impedance | 50 ohms | ||
Continuous Average Power | 200 W maximum (input ports), 500 W maximum (Common port) | ||
Peak Envelope Power | 1 kW maximum (input ports) 5 kW maximum (Common port) | ||
IM Performance(all ports) | <-117 dBm (-160 dBc) typical (2× +43 dBm tones) all bands | ||
DC Pass Current/AISG Pass (Port 1 or Port 2 to COM) | 3A/AISG signal (2.176 Mhz) per AISG 2.0 |
Mechanical Specification
Model | Twin | Quad |
Connectors | 8 × 4.3-10 (or Nex10TM or 2.2-5) female | 16 × 4.3-10 (or Nex10TM or 2.2-5) female |
Dimensions w/Bracket | 7.69 × 13.70 × 2.72 in. (195.3 × 348.0 × 69.0 mm) |
7.69 × 13.70 × 4.33 in. (195.3 × 348.0 × 110.0 mm) |
Housing Dimensions | 4.02 × 12.68 × 2.09 in. (102.0 × 322.0 × 53.0 mm) |
4.02 × 12.68 × 3.70 in. (102.0 × 322.0 × 94.0 mm) |
Weight | 5.2 lbs (2.35 kg) | 9.2 lbs (4.17 kg) |
Frontal Wind Load | 188.2 N @150km/hour | 188.2 N @150km/hour |
Lateral Wind Load | 18.4 N @150km/hour | 32.6 N @150km/hour |
Twin Outdoor Broadband Triplexer Outline Drawing | |
Quad Outdoor Broadband Triplexer Outline Drawing |
Parts & Accessories
TPO-333228-0-Tx | Twin 380-2700/3300-4200/5150-5925 Triplexer with No DC/AISG pass-through |
TPO-333228-1-Tx | Twin 380-2700/3300-4200/5150-5925 Triplexer with DC/AISG pass-through on 380-2690 path |
TPO-333228-0-Qx | Quad 380-2700/3300-4200/5150-5925 Triplexer with No DC/AISG pass-through |
TPO-333228-1-Qx | Quad 380-2700/3300-4200/5150-5925 Triplexer with DC/AISG pass-through on 380-2690 path |
Option (-x) | Description |
-2 | 4.3-10 female connectors |
-4 | Nex10TM female connectors |
-5 | 2.2-5 female connectors |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|