Wideband Hybrid Combiner | HYO-67-2xx | |||
|
Overview
CCI’s Wideband 2-Way Hybrid Combiner with Coupler provides a solution where combining two RF inputs into one or two common outputs is required. The unit is housed in a weatherproof outdoor enclosure for outdoor basestation or tower mount applications. Technical Description: CCI’s Outdoor Wideband 2-Way Hybrid Combiner covers the full 617 - 2690 MHz spectrum. The unit is housed in an IP67 moisture proof enclosure, with IP67 moisture proof connectors suited for long-life. The combiner can be wall or pole mounted.
|
Electrical
RF Parameters | Ports | Frequency(MHz) | Specification |
Insertion Loss | Input* to Output* | 617 - 2690 | 3.05 dB ± 0.4 dB |
Input* to Coupler | 617 - 2690 | 34 dB ± 10 dB | |
Isolation | Input* to Input* | 617 - 2690 | 30 dB min. , 32 dB typ. |
Return Loss | All Ports | 617 - 2690 | 25 dB min. |
*Input Refers to Ports 1-2 and Output Refers to Ports 3-4 |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 500 W maximum (per port) |
Peak Envelope Power | 3 kW maximimum |
Intermodulation Performance | <-160 dBc (-117 dBm) minimum, <-165 dBc (-122 dBm) typ. (2 × 43 dBm carriers) |
DC Pass Current/AISG Pass | DC paths: Port 1 to Port 3; Port 2 to Port 4; (max 6.5 A per AISG 2.0) |
Mechanical
Parameters | HYO-67-2F1 | HYO-67-2F2 |
Input Connectors | 7-16 DIN female × 2 | 4.3-10 female × 2 |
Output Connectors | 7-16 DIN female × 2 | 4.3-10 female × 2 |
Coupler Connector | SMA female x 1 | |
Dimensions (body only)(H×W×D) | 1.89 × 6.65× 1.61 in. (48.0 × 169.0 × 41.0 mm) | |
Dimensions (incl. brackets)(H×W×D) | 5.04 × 7.68 × 2.20 in. (128.0 × 195.0 × 56.0 mm) | |
Weight with brackets | 2.6 lbs (1.18 Kg) | |
Mounting | Pole/Wall mounting bracket |
2-Way Hybrid Combiner Outline Drawing with DIN Connectors | |
2-Way Hybrid Combiner Outline Drawing with 4.3-10 Conneectors |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, GR-63-CORE 4.3.1, EN 60529 IP65 & IP67 |
|