Outdoor Diplexer | DPO-7126-xxx | |||
|
Overview
The CCI Outdoor Diplexer passes the PCS and AWS bands covering 1695-2180 MHz on its low band input port and the full BRS band which covers 2496-2690 MHz on its high band input port. The Diplexer combines the low band and high band signals on to a common port and is specifically intended for use in multi-band systems with limited feeder lines. The Diplexer facilitates the addition of new technologies including LTE and new spectrum to existing sites while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and significantly reduces the total cost to upgrade a site. Technical Description: The CCI Outdoor Diplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the PCS/AWS with the BRS bands on to a common feeder line. The fully weatherproof tower mount outdoor Diplexer provides DC and AISG signal pass-through on either of the band specific ports, enabling power and control for TMA's & RET antennas. The Smart Bias-Tee architecture passes the DC and AISG carrier frequency from any one of the input ports to the common port while blocking the DC and AISG signals from being re-injected into the other input ports. The Diplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | COMMON | 1695 - 2180 | 18 dB minimum, 20 dB typical |
2496 - 2690 | 18 dB minimum, 20 dB typical | ||
PCS/AWS | 1695 - 2180 | 18 dB minimum, 20 dB typical | |
BRS | 2496 - 2690 | 18 dB minimum, 20 dB typical | |
Insertion Loss | COMMON to PCS/AWS | 1695 - 2180 | 0.2 dB typical, 0.25 dB maximum |
COMMON to BRS | 2496 - 2690 | 0.2 dB typical, 0.25 dB maximum | |
Rejection | COMMON to PCS/AWS | 1695 - 2180 | 50 dB minimum |
COMMON to BRS | 2496 - 2690 | 50 dB minimum | |
Isolation | AWS/PCS to BRS | 1695 - 2180 | 50 dB minimum |
BRS to AWS/PCS | 2496 - 2690 | 50 dB minimum |
GeneralCharacteristics | |
Impedance | 50 ohms |
Continuous Average Power | 250 W maximum (input ports), 500 W maximum (Common port) |
Peak Envelope Power | 1 kW maximum (input ports), 3 kW maximum (Common port) |
Intermodulation Performance | <-117 dBm (-160 dBc) at 2 × +43 dBm tones all bands |
DC Pass Current/AISG Pass | 3A/AISG signal (2.176 Mhz) per AISG 2.0 on either input port |
Mechanical
Model | DPO-2126-x-Sx | DPO-2126-x-Tx | DPO-2126-x-Qx |
Modularity | Single | Twin | Quad |
Weight with brackets | 3.7 lbs (1.6 Kg) | 7.3 lbs (3.3 Kg) | 14.4 lbs (6.6 Kg) |
Dimensions with brackets | 5.94 x 7.94 x 2.02 in. (151 x 201.8 x 51.4 mm) |
5.94 x 7.94 x 4.07 in. (151 x 201.8 x 103.4 mm) |
5.94 x 7.94 x 8.17 in. (151 x 201.8 x 207.4 mm) |
Dimensions single enclosure | 3.03 x 7.42 x 1.92 in. (77 x 188.5 x 48.8 mm) | ||
Connectors | 3 × 7-16 DIN female long neck or 3 × 4.3-10 female | ||
Mounting | Pole/Wall mounting bracket |
Outdoor Diplexer Outline Drawing |
Accessories
SCU-AISG2-3 | AISG 2.0 Site Controller |
RET-CBK | AISG Cable Kit |
BT-0821-DMDF-AG-O | DIN-Male RF Port, DIN-Female RF+DC+AISG Port |
BT-0821-DFDM-AG-O | DIN-Female RF Port, DIN-Male RF+DC+AISG Port |
BT-0821-DFDF-AG-O | DIN-Female RF Port, DIN-Female RF+DC+AISG Port |
Parts & Accessories
DPO-7126-x-S1 | Outdoor Diplexer with 7-16 DIN connectors |
DPO-7126-x-S2 | Outdoor Diplexer with 4.3-10 connectors |
DPO-7126-x-T1 | Outdoor Twin Diplexer with 7/16 DIN connectors |
DPO-7126-x-T2 | Outdoor Twin Diplexer with 4.3-10 connectors |
DPO-7126-x-Q1 | Outdoor Quad Diplexer with 7/16 DIN connectors |
DPO-7126-x-Q2 | Outdoor Quad Diplexer with 4.3-10 connectors |
Option (-x) | Description |
-0 | No DC/AISG Pass through |
-1 | DC/AISG Pass through Low Band to COMMON, DC Block on all other input ports |
-2 | DC/AISG Pass through High Band to COMMON, DC Block on all other input ports |
-S | Smart Bias-T, DC/AISG Pass through on either port |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|