Outdoor Diplexer | DPO-1973-xxx |
|||
|
Overview
The CCI Outdoor Diplexer combines the PCS bands covering 1850-1995 MHz on its low band input port and the full AWS and WCS bands covering 1695-1780 and 2110-2360 MHz on its high band input port. The Diplexer combines the low band and high band signals on to a common port and is specifically intended for use in multi-band systems with limited feeder lines. The Diplexer facilitates the addition of new technologies including LTE to existing sites while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and significantly reduces the total cost to upgrade a site. Technical Description: The CCI Outdoor Diplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the PCS band with the AWS-WCS bands on to a common feeder line. The fully weatherproof tower mount outdoor diplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | COMMON | 1695 - 1780 | 18 dB minimum, 20 dB typical |
1850 - 1995 | 18 dB minimum, 20 dB typical | ||
2110 - 2360 | 18 dB minimum, 20 dB typical | ||
PCS | 1850 - 1995 | 18 dB minimum, 20 dB typical | |
AWS/WCS | 1695 - 1780 | 18 dB minimum, 20 dB typical | |
2110 - 2360 | 18 dB minimum, 20 dB typical | ||
Insertion Loss | COMMON to PCS | 1850 - 1995 | 0.3 dB typical, 0.4 dB maximum |
COMMON to AWS/WCS | 1695 - 1780 | 0.3 dB typical, 0.45 dB maximum | |
2110 - 2360 | 0.25 dB typical, 0.35 dB maximum | ||
Isolation | COMMON to PCS | 1695 - 1780 | 50 dB minimum |
2110 - 2360 | 50 dB minimum | ||
COMMON to AWS/WCS | 1850 - 1995 | 50 dB minimum |
General Characteristics | |||
General Impedance | 50 ohms | ||
Continuous Average Power | 200 W maximum (input ports), 500 W maximum (Common port) | ||
Peak Envelope Power | 1 kW maximum (input ports), 3 kW maximum (Common port) | ||
Intermodulation Performance | <-117 dBm (-160 dBc) at 2 × +43 dBm tones all bands | ||
DC Pass Current/AISG Pass (Any Port to COMMON port) | 3A/AISG signal (2.176 MHz) per AISG 2.0 | ||
Modem Option | 9600 Baud per AISG 2.0/3GPP TS 25.461 |
Mechanical
Model | DPO-1973-x-S2 (Single) | DPO-1973-x-T2 (Twin) | DPO-1973-x-Q2 (Quad) |
Connectors | 3 × 4.3-10 female | 6 × 4.3-10 female | 12 × 4.3-10 female |
Dimensions w/Bracket (H×W×D) | 8.35 × 12.20 × 2.28 in. (212.0 × 310.0 × 58.0 mm) |
8.35 x 12.20 x 3.54 in. 212.0 x 310.0 x 90.0 mm) |
8.35 x 12.20 x 6.02 in. 212.0 x 310.0 x 153.0 mm) |
Housing Dimensions (H×W×D) | 4.41 × 12.20 × 1.89 in. (112.0 × 310.0 × 48.0 mm) |
4.41 x 12.20 x 3.15 in. (112.0 x 310.0 x 80.0 mm) |
4.41 x 12.20 x 5.63 in. (112.0 x 310.0 x 143.0 mm) |
Weight with brackets | 5.3 lbs (2.4 kg) | 8.9 Lbs. (4.0 kg) | 16.0 Lbs. (7.3 kg) |
Frontal Wind Load @ 150 km/hour | 160.1 N (36.0 Lbs.) | 160.1 N (36.0 Lbs.) | 160.1 N (36.0 Lbs.) |
Lateral Wind Load @ 150 km/hour | 18.3 N (4.1 Lbs.) | 30.4 N (6.81 Lbs) | 54.4 N (12.2 Lbs) |
Mounting | Pole/Wall mounting bracket |
Outdoor Diplexer (DPO-1973-xxx) Outline Drawing |
Parts & Accessories
DPO-1973-S-S2 | Single PCS - AWS/WCS Diplexer with 4.3-10 connectors and Smart Bias-T for DC/AISG pass through |
DPO-1973-S-T2 | Twin PCS - AWS/WCS Diplexer with 4.3-10 connectors and Smart Bias-T for DC/AISG pass through |
DPO-1973-S-Q2 | Quad PCS - AWS/WCS Diplexer with 4.3-10 connectors and Smart Bias-T for DC/AISG pass through |
DPO-1973-M-S2 | Single PCS - AWS/WCS Diplexer with 4.3-10 connectors and AISG Modem and Output Port |
DPO-1973-M-T2 | Twin PCS - AWS/WCS Diplexer with 4.3-10 connectors and AISG Modem and Output Port |
DPO-1973-M-Q2 | Quad PCS - AWS/WCS Diplexer with 4.3-10 connectors and AISG Modem and Output Port |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|